Flush Mount Electrical Enclosure
ONLYWY’s flush-mount enclosures, also known as recessed or wall-mount enclosures, mount flush to the wall. Embedded design to the wall, as the name suggests. These enclosures may be utilized in a range of contexts, including offices and industrial plants, and provide an efficient method to store, organize, and secure critical equipment. Our flush-mount electrical enclosure manufacturing provides a clean, enhanced look wherever it is installed.
Flush Mount Electrical Enclosure manufacturer in China
ONLYWY’s Flush Mount Electrical Enclosure offers a reliable solution to organizing and protecting electrical equipment in a wall with limited workspace for your project.
With precise openings, mounting methods, and surface finish options. Only the door or front panel is visible. These enclosures are perfect for offices, retail stores, and back-office setups, offering a range of sizes, types, and structures, as well as flexible wiring management.
Our factory supports OEM and ODM customization in size, shape, cutout, mounting options, logo or labeling, and construction, with special finishes to match your project needs. Flush Mount Box materials include stainless steel, carbon steel, galvanized steel, aluminum, and cold-rolled steel plate, all powder-coated to meet your NEMA type and IP protection rating, and in various colors you want based on your standard.
Welcome to Link ONLYWYPOWER team, where we help boost your business with our high-quality services.
Benefits for Flush Mount Electrical Enclosure Use
Using ONLYWY’s Flush Mount Enclosure offers numerous advantages.
They conform directly to the wall, rather than being installed along the floor, saving space. This is especially useful in small spaces with limited floor space. Recessed mounting flanges allow the Flush Mount Electrical Enclosure to be installed in wall cavities, saving space and ensuring safety in narrow rooms, while also being easy to drill and install.
It will eliminate the tripping hazard that can occur with floor-mounted enclosures. This reduces the risk of tripping accidents. Protects and improves component lifespan.Sensitive electronics, Simplifies system assembly & repair.
Discover Applications of ONLYWY Flush Mount Electrical Enclosure Provided
1. Residential Buildings: Residential distribution boxes & low-voltage information boxes.
Residential Distribution Box: Each household typically has a flush wall-mount electrical enclosure at the entrance, responsible for distributing, controlling, and protecting circuits for lighting, sockets, air conditioning, etc., throughout the home.
Low-Voltage Information Box: Centrally manages the access and distribution of low-voltage lines for telephone, internet, cable TV, smart home systems, etc.
2 . Commercial and Public Buildings: Floor distribution rooms, lighting control boxes, emergency lighting and power boxes, hospital ward medical wiring.
Floor Distribution Rooms: Embedded or semi-embedded electrical boxes are installed on each floor of office buildings, shopping malls, hotels, hospitals, etc., responsible for supplying power to various areas on that floor.
Lighting Control Boxes: Specifically used to control lighting in public areas (such as corridors and lobbies), sometimes connected to building automation systems to achieve intelligent control, such as timing and sensing.
Emergency Lighting and Power Boxes: Provide power to critical equipment, such as emergency lighting, smoke exhaust fans, and fire pumps, during emergencies.
Hospital Ward Medical Equipment Strips: In hospital wards, embedded medical equipment strips integrate interfaces for medical gases such as oxygen and negative-pressure suction, as well as power sockets; their interiors house sophisticated flush-mount electrical enclosure units.
3. Industrial and Manufacturing: Industrial environments place higher demands on the protection level, reliability, and professionalism of electrical cabinets.
Production Line Control Station: On production lines, Flush Mount Electrical Enclosure houses PLCs (Programmable Logic Controllers), frequency converters, servo drives, etc., used to control equipment such as robotic arms, conveyors, and machining centers.
Inside Automated Equipment: Many automated single-machine devices, such as CNC machine tools, packaging machines, and injection molding machines, have a Flush Mount Enclosure directly embedded in the equipment body, resulting in a compact structure.
Process Control Room: In chemical plants, oil refineries, etc., the main control room typically has a large console, while local control boxes or instrument boxes, and flush-mount or explosion-proof enclosures are located near each process unit on-site for local monitoring and equipment start-up and shutdown.
Data Center & Server Room: While server racks and network cabinets in a server room are not entirely “embedded” in the wall, the concept is to embed them within the rack row, responsible for distributing power and managing the network for the entire row of servers.
4. Transportation Systems & Energy Facilities: Subway/high-speed rail stations, tunnels, energy facilities, substations, and new energy power plants.
Subway/High-Speed Rail Stations: Power distribution and control boxes for platform screen doors, automatic ticket vending machines, security screening equipment, and signage are typically embedded in platform walls or in equipment rooms.
Tunnels: To save workspace, control boxes for lighting, ventilation, monitoring, and fire protection systems are typically flush-mounted.
Substations: In the secondary equipment room of a substation, protection and control devices, power quality management devices, etc., are often installed in a flush-mount enclosure.
New Energy Power Plants: Photovoltaic inverters and wind power converters are sometimes also flush-mounted into prefabricated cabins.
5. Special Applications and Customized Scenarios: Ships and vehicles, clean rooms and laboratories, smart homes and smart buildings.
Ships and vehicles: Space in ship cabins and high-speed train carriages is extremely valuable. All electrical distribution, lighting control, and communication equipment must be flush-mounted in the wall panels and be shock-resistant, moisture-proof, and corrosion-resistant.
Cleanrooms and Laboratories:To meet dust-free and sterile requirements, all electrical enclosures must be flush-mounted in the walls, flush with the wall surface, to avoid dust accumulation and facilitate cleaning.
Smart Homes and Smart Buildings: The core of a smart home system—the smart host, the power and low-voltage wiring center, and security control modules—is integrated into a flush-mounted home distribution box/smart box that is aesthetically pleasing.
Flush Mount Electrical Enclosure Series
The sizes below are our normal made. If you want to make other sizes. Just tell us your requirements.
|
Model |
High/mm |
Width/mm |
Depth/mm |
|---|---|---|---|
| JXF2215 | 200 | 200 | 150 |
| JXF2515 | 250 | 200 | 150 |
| JXF2315 | 300 | 200 | 150 |
| JXF2320 | 300 | 200 | 200 |
| JXF25315 | 300 | 250 | 150 |
| JXF25320 | 300 | 250 | 200 |
| JXF3315 | 300 | 300 | 150 |
| JXF3320 | 300 | 300 | 200 |
| JXF3325 | 300 | 300 | 250 |
| JXF3415 | 400 | 300 | 150 |
| JXF3420 | 400 | 300 | 200 |
| JXF3425 | 400 | 300 | 250 |
| JXF4415 | 400 | 400 | 150 |
| JXF4420 | 400 | 400 | 200 |
| JXF4425 | 400 | 400 | 250 |
| JXF3515 | 500 | 300 | 150 |
| JXF3520 | 500 | 300 | 200 |
| JXF3530 | 500 | 300 | 300 |
| JXF4515 | 500 | 400 | 150 |
| JXF4520 | 500 | 400 | 200 |
| JXF4525 | 500 | 400 | 250 |
| JXF4530 | 500 | 400 | 300 |
| JXF5515 | 500 | 500 | 150 |
| JXF5520 | 500 | 500 | 200 |
| JXF5525 | 500 | 500 | 250 |
| JXF4615 | 600 | 400 | 150 |
| JXF4620 | 600 | 400 | 200 |
| JXF4625 | 600 | 400 | 250 |
| JXF4630 | 600 | 400 | 300 |
| JXF5615 | 600 | 500 | 150 |
| JXF5620 | 600 | 500 | 200 |
| JXF5625 | 600 | 500 | 250 |
| JXF5630 | 600 | 500 | 300 |
| JXF6615 | 600 | 600 | 150 |
| JXF6620 | 600 | 600 | 200 |
| JXF6625 | 600 | 600 | 250 |
| JXF4720 | 700 | 400 | 200 |
| JXF4730 | 700 | 400 | 300 |
| JXF5715 | 700 | 500 | 150 |
| JXF5720 | 700 | 500 | 200 |
| JXF5725 | 700 | 500 | 250 |
| JXF6720 | 700 | 600 | 200 |
| JXF6725 | 700 | 600 | 250 |
| JXF6820 | 800 | 600 | 200 |
| JXF6825 | 600 | 250 | 800 |
| JXF6830 | 800 | 600 | 300 |
| JXF8820 | 800 | 800 | 200 |
| JXF8825 | 800 | 800 | 250 |
| JXF8830 | 800 | 800 | 300 |
| JXF6 1020 | 1000 | 600 | 200 |
| JXF6 1025 | 1000 | 600 | 250 |
| JXF6 1030 | 1000 | 600 | 300 |
| JXF8 1020 | 1000 | 800 | 200 |
| JXF8 1025 | 1000 | 800 | 250 |
| JXF8 1030 | 1000 | 800 | 300 |
| JXF8 1040 | 1000 | 800 | 400 |
| JXF10 1025 | 1000 | 1000 | 250 |
| JXF10 1030 | 1000 | 1000 | 300 |
| JXF6 1220 | 1200 | 600 | 200 |
| JXF6 1225 | 1200 | 600 | 250 |
| JXF6 1230 | 1200 | 600 | 300 |
| JXF8 1220 | 1200 | 800 | 200 |
| JXF8 1225 | 1200 | 800 | 250 |
| JXF8 1230 | 1200 | 800 | 300 |
| JXF10 1225 | 1200 | 1000 | 250 |
| JXF10 1230 | 1200 | 1000 | 300 |
| JXF10 1240 | 1200 | 1000 | 400 |
| JXF12 1225 | 1200 | 1200 | 250 |
| JXF12 1230 | 1200 | 1200 | 300 |
| JXF6 1430 | 1400 | 600 | 300 |
| JXF8 1430 | 1400 | 800 | 300 |
| JXF10 1430 | 1400 | 1000 | 300 |
| JXF10 1440 | 1400 | 1000 | 400 |
| JXF12 1430 | 1400 | 1200 | 300 |